Lions Dental Supply And Equipment Telephone Number

Lion's Dental Supply & Equipment

Quality Dental Operatory Equipment, Autoclaves & Supplies...All at the Lowest Prices !!!                     
Lions Dental Supply and Equipment
Home
Face Masks
Supplies
Air Abrasion System- Dental
Air Compressors-Dental
Air Polishers & Scalers
Amalgamators
Apex Locators
Autoclaves & Sterilizers
Bleaching Dental Light Systems
Chairs Operatory
Curing Light Units- Halogen & Led
Delivery Units & Mobile Carts
Digital X-Ray Sensors
Electrosurgery Units For Dental
Endodontic Rotary Systems
Endodontic Obturation & Thermal Condensors
Equipment
Film Processors
Handpieces
Implant Motor Systems
Intraoral Cameras
Intraoral Digital Scanners
Laboratory Equipment
Laboratory Micro Motors
Lasers
Mobile Carts
Operatory Lights
Operatory Packages
Phosphor Plate Scanner Digital X-Ray System
Piezo Scalers
Portable Delivery Units
Sterilizers
Ultrasonic Cleaners
Ultrasonic Scalers
Vacuum Systems
X-Ray Equipment
X Ray Units
Pitfalls of Handheld Dental X-Rays Units
Owandy RX Pro DC Dental X-Ray Unit
Owandy RX DC Pro Mobile Dental X-Ray Unit
Owandy-RX DC Dental Intraoral X-Ray Unit
Owandy-RX DC Mobile Dental Intraoral X-Ray Unit
Trident RiX70DC Wall Mounted Dental X-Ray Unit
Rayos DC Intra-Oral X-Ray
XLine XDC Intra-Oral Dental X-Ray Unit
Nomad Pro 2 Hand Held X-Ray Unit
MaxRay Cocoon Dental HandHeld X-Ray Unit
Dexcowin Cocoon Dental HandHeld X-Ray Unit
Mobile X Dental HandHeld Intra Oral X-Ray Unit
Max Ray Digital Handheld Dental X-ray
Port-X IV Handheld X-Ray Unit
Zen-Px2 Handheld X-Ray Unit
iRay D4 Digital Handheld Dental X-ray
RexTar X Handheld X-Ray Unit
Woodpecker AiRay Lite Portable Handheld X-Ray Unit
Remedi Remex T-100 Dental HandHeld X-Ray Unit
X-Vision Portable Handheld X-Ray Unit
Woodpecker AiRay Pro HandHeld Dental X-Ray Unit
Owandy RX Portable HandHeld Dental X-Ray Unit
Ecotron DT-703 Portable HandHeld Dental X-Ray Unit
XRD RAY98P Dental Portable X-Ray Unit
I-Max 2D Wall Mounted Panoramic Unit
I-Max Easy Digital Panoramic Unit
I-Max Touch Digital Pan/Ceph Unit
I-Max Touch 3D Digital Pan/Ceph Unit
Papaya Panoramic X-Ray Machine
Papaya Plus Panormaic and Ceph Unit
Papaya 3D Panoramic Imaging Unit
Papaya 3D Digital Panoramic And Cephalometric X-Ra
Acteon X-MIND Prime 2D Digital Panoramic X Ray Uni
Acteon X-MIND Prime Ceph Digital Panoramic Machine
Acteon X-MIND Prime 3D CBCT X-Ray Unit
Acteon X-Mind Trium 3D CBCT X-Ray Unit
Bi-Image-X Evolution Dental X-Ray Unit
Bi-Image-X Evolution Dental X-Ray Mobile Unit
Corix 70 Plus-USV-WM Digital X-Ray Machine
Corix Digital Pro 70 MM Dental Mobile X-Ray Unit
Vector Maxray 70 Wall Mounted Dental X-Ray Unit
iRay D3 Digital Handheld Dental X-ray
iRay A6 Digital Handheld Dental X-ray
Sky View TomoGraph X-Ray Unit
Five Questions to Ask When Buying a Dental X-Ray
Digital Dental X Ray Machine Cost
Specials
terms and conditions
Leasing And Financing
Rentals
FAQ
Career opportunities

MaxRay Cocoon Dental Intra Oral HandHeld X-Ray Unit


MaxRay Cocoon Dental Intra Oral HandHeld X-Ray Unit Item # BX-7017

MaxRay Cocoon Dental Intra Oral HandHeld X-Ray Unit

 

At less the 5lbs the MaxRay Cocoon HandHeld X-ray Unit is lightweight and ready to move. The camera shape design allows the MaxRay Cocoon X-Ray Unit to be held by either one hand or by a carrying strap. Easily finish an FMX in just a few minutes.

The MaxRay Cocoon X-Ray has an easy to use display and control function and even comes equipped with Voice Prompts!

The MaxRay Cocoon Dental Intra Oral HandHeld X-Ray Unit has a Long-Life Lithium Battery, the best battery technology on the market today, taking over 500 x-ray shots on a single battery charge compared to only 100 with other systems. Forget to charge the battery? No sweat. Just plug in the power adapter to the nearest outlet and take continue to taking x-rays.

• Eliminate multiple X-Ray units.
• Simplify your design and reduce your cabinet costs.
• Eliminate between operatory shielding

Reg $ 7,999  Sale 4,999

 


The MaxRay Cocoon is Lightweight. Portable. Handheld.

Improved Workflow

Take radiographs nearly twice as fast then a conventional X-Ray systems, saving you approximately 120 work hours a year. How much is your conventional X-Ray system costing you?

Zero Leakage Design

The MaxRay has under gone extensive testing to ensure it is safe to use for the operator and the patient. The MaxRay interior components are thoroughly sealed with multiple sheets of lead (Pb) to block out any leakage radiation.

High Resolution X-Rays

The MaxRay Cocoon produces sharp, high resolution images with a 0.4mm focal point. At 70kV the MaxRay generator produces clear images while reducing patient dose.

A Better Patient Experience

Spend more time with your patients & reduce patient movement. Gone are the days you have to leave the patient to take an x-ray. Why waste time walking back and forth to take an x-ray?

Less Retakes

How many times have you set up your conventional wall mounted x-ray generater, only to have it drift as you go to take an x-ray? The MaxRay Cocoon Handheld Dental X-Ray can reduce the number of retakes by up to 50%.

FDA Approved

MaxRay Cocoon Dental Intra Oral HandHeld X-Ray Unit


MaxRay Cocoon Dental HandHeld X-Ray Unit Brochure

Maxray Cocoon Specifications :

Tube Voltage: 70 kV
Tube Current: 2mA (External Power) / 1. 7 mA (Internal Battery)
Tube Focal Spot Size: 0.4 mm
Power Consumption: 336 VA, 321VA
Cooling Method: Oil Cooling Method
Total Filtration: Over 2.3 mm Al (Inherent Filtration: 1.0 mm Al) °
Target Angle: 12.5°
Exposure Time Range: 0.05 -1.0 sec
Exposure Time Interval between the exposure : 0.01 sec
Distance to Target (Distance between Target and Focal Spot : 18 cm {7 inch)
Body Dimension: 322(L) x 134(W) x 262(H) [mm]
Body Weight : 4.8 lb (Back Scattered Shield excluded)
Battery : 16.8 V
Battery exposure capacity : 500 Shots with full charged
Voice Guide pre recorded
Narration for quick user training
Wide UI screen
Item Sku# BX-7017
2 Year Warranty

MaxRay Cocoon Dental HandHeld X-Ray Unit Screen


Application for COCOON HandHeld X-Ray unit in Dental and Veterinary

COCOON X-Ray Unit has enough power and handy weight to be used for both general treatment and operation.

Dental
When mobility is needed most frequently, x-rays are important as a progress check in many dental surgical operations. Moving a patient under anesthesia for a wall-mounted x-ray is not only inconvenient and time-consuming for the doctor, but risky for the patient. The COCOON portable handheld x-RAY device allows for true one-hand portable X-RAY shots: as many as 500 shots before recharging. It is more efficient for dentists and oral surgeons, and the operator is also protected by advanced safety features.

Veterinary
COCOON portable handheld X-RAY device provides veterinarians instant and accurate diagnoses on-site, eliminating the need to transport heavy animals for body and oral X-RAY imaging.

In many pet clinics pets requiring examination for illness or infection face risk of high radiation exposure, especially small pet oral scans. But COCOON portable handheld X-RAY device uses low radiation, avoiding unnecessary exposure for furry family members.

MaxRay Cocoon Dental HandHeld X-Ray Unit Complete Kit


MaxRay Cocoon Portable Handheld Dental X-Ray

The MaxRay Cocoon is Lightweight. Portable. Handheld.



Cocoon Dental Intra Oral HandHeld X-Ray Unit MPN# BX-7017

reg $ 7,259   Sale $4,999


MaxRay Coccon Replacement Accessories


MaxRay Neck Strap & Holster # DX-P5020 $ 159

MaxRay Battery   #DX-P565 $ 399

MaxRay 5 Year Extended Warranty Replacement # BX-WAR $ 549

MaxRay 8" Mounting Tablet Mounting Kit # DX-P400 $ 399

MaxRay Lead infused Scatter Shield #DX-P505  $ 289
Max Ray Mobile Rolling Stand #DX-P545  $ 1,499
Max Ray Remote Switch With Wire #DX-P555  $ 75
AC Adapter For Direct Connection #DX-P525  $ 329
Max Ray Battery And Charger #DX-P515  $ 439
Operator X-Ray Apron With Holster Strap #DX-P535  $ 299

.



MaxRay Cocoon Training Manual DownLoadMaxRay Cocoon Training Manual
The training manual for the MaxRay Cocoon.

MaxRay Cocoon Training Exam DownLoad MaxRay Cocoon Training Exam
The training exam for the MaxRay Cocoon.

MaxRay Cocoon Training Exam Key DownLoad MaxRay Cocoon Training Exam Key
The correct answers to the MaxRay training exam.

MaxRay Cocoon User Manual DownLoad MaxRay Cocoon User Manual
The MaxRay User Manual

MaxRay Cocoon Initial Setup Manual DownLoad MaxRay Cocoon Initial Setup Manual
The MaxRay Initial Setup

MaxRay Cocoon Extended Warranty DownLoad MaxRay Cocoon Extended Warranty
The MaxRay Cocoon Extended Warranty Termsp


MaxRay Cocoon Training Certificate
MaxRay Training Certificate for completion of training



MaxRay State Approval

The MaxRay is FDA Approved but each state has their own approvals as well for Handheld X-Ray Units. Please check your states Approval Status.

Alabama

APPROVED

Apply for exemption / must document training manual

Alaska

APPROVED

Arizona

APPROVED

R12-1-610.01. Handheld Intraoral Dental Radiographic Unit Requirements For Use A. Registrants are subject to the following requirements for Intraoral dental radiographic units designed to be operated as a hand?held unit: 1. For all uses: a. Operators of hand?held intraoral dental radiographic units shall be specifically trained to operate such equipment. b. A handheld intraoral dental radiographic unit shall be held without any motion during a patient examination. A tube stand may be utilized to immobilize a handheld intraoral dental radiographic unit during patient examination. c. The operator shall ensure there are no bystanders within a radius of at least six feet from the patient being examined with a handheld intraoral radiographic unit. 2. Additional requirements for operatories in permanent facilities: a. Handheld intraoral dental radiographic units shall be used for patient examinations in dental operatories thatmeet the structural shielding requirements specified by the Agency or by a qualified health or medical physicist. b. Handheld intraoral dental radiographic units shall not be used for patient examinations in hallways and waiting rooms. B. Hand?held units may only be used in a manner as specified on the registration issued.

Arkansas

APPROVED

California

APPROVED

1. The portable dental X-ray system being used has received FDA approval and is being used in a manner consistent with that approval; 2. A backscatter shield provided by the manufacturer, which provides not less than 0.25 mm lead equivalent, must be permanently affixed in place at all times; the X-ray system may not be used if this component becomes broken or dislodged; 3. Personnel monitoring devices must be worn by all individuals operating portable dental X-ray systems. The personnel monitoring must be evaluated on a monthly basis, and records must be available for review by the Department; 4. All personnel must receive training in the safe use of these X-ray systems; records of training must be available for review by the Department.Must wear personal monitoring device (Nomad, monitoring device not required)

Colorado

APPROVED

Connecticut

APPROVED

Deleware

APPROVED

Must apply for variance.

Contact Delaware Radiology Board: (302)744-4546

Florida

Cleared by Regulation

A Dosimeter is Required for use.

Georgia

APPROVED

1. Portable equipment shall be used only for examinations where it is impractical for medical purposes, to transfer the patient to the x-ray suite. 290-5-22.04 (4) (g) 2. When this portable device is used, a pistol grip and a permanently attached back scatter device must be part of the equipment. The operator shall not be able to remove either the grip or the back scatter device. 3. All operators will wear a lead apron when making exposures. 4. If any operator has a need to use a portable handheld dental machine on a regular basis (see reference no. 1) they shall be provided with a dosimetry badge. 5. Equipment shall be secured against unauthorized use by a key or password.

Hawaii

APPROVED

The operator shall use a lead apron and thyroid collar while operating a handheld dental xray unit.

Idaho

APPROVED

Illinois

APPROVED

Indiana

Confirmed with conditions

Must email/call Dave Nauth (317) 233-7563 [email protected] a letter requesting a variance. Also must use an apron.

Iowa

APPROVED

Must apply for a variance.

Please call Iowa Radiology Board at (515) 281-0415

Kansas

NOT APPROVED

Kentucky

APPROVED

Dosimeter Required, Apron Required, See vendor requirement: Must request an exemption send request in writing to: Kentucky Radiation Health, 275 E Main St.,
Mailstop: HS1C-A, Frankfort, KY 40621, Fax 502-564-1492

Louisiana

APPROVED

Must keep shield in place, Use in treatment area, wear dosimeter badge, must submit statement regarding storage, Dr. must submit training certificate.

Maine

APPROVED

Maryland

APPROVED

Cleared by regulation. Must apply for variance.

Contact Maryland Radiology Board at (410) 537-3186

Massachusetts

APPROVED

Contact Karan Farris Massachusetts Radiology Board at (617) 242-3055 EXT 2011 for questions.

(F) Hand Held Intraoral Dental Radiographic Units (1) For all uses:
(a) Operators of hand held intraoral dental radiographic units shall be specifically trained to operate such equipment.
(b) When operating a hand held intraoral dental radiographic unit, operators shall wear a lead apron and thyroid collar, unless otherwise authorized by the Agency or a qualified health or medical physicist.
(c) A hand held intraoral dental radiographic unit shall be held without any motion during a patient examination. A tube stand may be utilized to immobilize a hand held intraoral dental radiographic unit during patient examination.
(d) Unless otherwise authorized by the Agency, a hand?held intraoral dental radiographic unit shall be used with a secondary radiation block.
(e) The operator shall ensure there are no bystanders within a radius of at least six feet from the patient being examined with a hand held intraoral radiographic unit.
(2) Additional requirements for operatories in permanent facilities:
(a) Handheld intraoral dental radiographic units shall be used for patient examinations in dental operatories that meet the structural shielding requirements specified by the Agency or by a qualified health or medical physicist.
(b) Handheld intraoral dental radiographic units shall not be used for patient examinations in hallways and waiting rooms.

Michigan

NO CONFIRMATION

May be able to apply for variance.

Minnesota

APPROVED

Does require variance (recommend the office request variance prior to purchase)

Contact Minnesota Radiology Board at (651) 201-4533

Mississippi

NO CONFIRMATION

May apply for variance. Contact Mississippi Radiology Board at (601) 987-6893

Missouri

APPROVED

Montana

APPROVED

Nebraska

NO CONFIRMATION

May be able to apply for variance. Call Nebraska Radiology Board at (402) 471-0560

Nevada

APPROVED

New Hampshire

APPROVED

New Mexico

APPROVED

Must get a variance: Justification for use, commitment to safety and security and training. Contact New Mexico Radiology Board at (505) 753-7256

Registration Form: https://www.env.nm.gov/nmrcb/documents/RadiationProducingMachineRegistration_RADServices_FinalApril2013.pdf

New Jersey

APPROVED

New York

APPROVED

North Carolina

APPROVED

  • Operator must wear a lead apron.
  • Facility must register the machines with this Section within 30 days of initial activation
  • Operators of the unit must complete the training provided by the manufacturer prior to use
  • A record of training must be retained for each operator (This should be a printed certificate)
  • Each operator must be authorized to utilize Dental x-ray equipment in NC
    Personnel monitoring must be worn by operators during use of the unit
    Lead aprons or whole body protective barriers of not less than 0.25 mm lead equivalent must be utilized by the operator
  • The registrant’s Written Radiation Safety Program must address use of the hand-held machine
  • The unit must be secured when not in use to prevent exposure by a non-authorized user
  • The back scatter shield must be in place for use of the device
  • At a minimum, E or F Speed Film or a digital sensor should be used for dental exams
  • A copy of this letter must be maintained by the registrant

North Dakota

APPROVED

Ohio

APPROVED

Oklahoma

APPROVED

Oregon

APPROVED

Pennsylvania

APPROVED

Rhode Island

APPROVED

See Part F Apendix D of RI Dental x-ray regulations for specifications for handheld use.

South Carolina

NOT APPROVED

South Dakota

APPROVED

Tennessee

APPROVED

Dosimeter Badge Required for use for (1) Year.

Contact Tennessee Radiology Board (615) 532-0399 for questions.

Texas

APPROVED

Utah

APPROVED

(12) Handheld Portable Dental X?ray Systems. (a) X-ray equipment designed to be hand?held shall comply with Section R313-28-31, excluding Subsection R313-28-31(5), and with Section R313-28-80, excluding Subsections R313-28-80(7)(b) and R313-28-80(11)(b). (b) Protective shielding of at least 0.5 millimeter lead equivalence shall be provided for the operator to protect the operator’s torso, hands, face, and gonads from backscatter radiation. If the protective shielding is a backscatter shield attached to the Dental x-ray unit, the shield shall be positioned as close to the patient as possible and the operator shall take care to remain in a protective position. (c) Portable radiation machines designed to be handheld are exempt from Subsection R313-28-35(7). The portable radiation machines shall be held by the tube housing support or handle and shall be used in accordance with the manufacturer’s operating procedures. (d) In addition to the requirements of Subsection R313-28-350(1), each operator shall complete the training program supplied by the manufacturer prior to using the Dental x-ray unit.
Records of training shall be maintained on file for examination by an authorized representative of the Director.

Vermont

APPROVED

Virginia

APPROVED

Must request variance, dosimeter, each user must read and make themselves familiar with the device. Contact Virginia Radiology Board at (804) 864-8170

Washington

APPROVED

Apron may be required. Contact Washington Radiology Board at (360) 236-3267

West Virginia

APPROVED

Wisconsin

APPROVED

Wyoming

APPROVED

Apron may be required. Contact Wyoming Radiology Board at (307) 777-4951


.